TM 11-6625-2638-30
Table 2-2. Fault Symptom Chart
GROUP
CONTROL/lNDICATOR/JACK
CORRECTIVE ACTION
1
ELECT (J1, J5, J2 Connector Group)
Perform steps 1 thru 10, 15 thru 19, and 22 thru 53 of table 2-3.
2
RCVR (J3, J4 Connector Group)
Perform steps 1 thru 21,52 thru 54, and 55d of table 2-3. If fault is related to SERVO
and GIMBAL cored switches, notify higher category maintenance.
3
ELECT TEST Lamps
Perform steps 1 thru 15 and 36 thru 46 of table 2-3.
4
MODE Switch
Perform steps 1 thru 10, 22, 27 thru 32, and 45 thru 50 of table 2-3.
5
SCAN, ΣΑΤ, Coding and TRACKING FILTER Switches
SCAN switch
TRACKING FILTER and RESET switches
ΣΑΤ switch and CODING/TRACKING switch
CODE switch
Perform steps 1 thru 10 and 33 thru 39 of table 2-3.
6
BITE/ADDRESS Group
Perform steps 1 thru 15, and 51 thru 54 of table 2-3.
7
ELECT Group Test Jacks
Check continuity of suspected jack per wirelist (table 2-4).
8
ELECT VOLTAGE switch
2-4