TM 11-6625-2638-12
Table 2-7. Scan, ∑ΑΤ, Code Tracking Filter Switches
Function
Item
Switch
Provides 10 separate simulated resolver posi-
1
SCAN switch
tion signals to electronic assembly.
(1 O-position rotary
switch) (S4)
Manually reset test set clock circuitry for BITE
2
RESET switch
and tracking tests.
(pushbutton
switch) (S13)
3
TRACKING FILTER
Selects simulated target position signals to
electronic assembly tracking filter.
switch (6-position
rotary switch) (S15)
4
Selects desired code number to determine
CODE switch (3-rotor,
8-position per rotor
switch)
(S2)
Activates SAT signal from test set to electronic
ON/OFF switch
5
(toggle switch)
assembly.
(S11)
Selects ∑ΑΤ coding or ∑ΑΤ tracking inputs to
CODING/
6
TRACKING
electronic assembly.
switch (2-position tog-
gle switch) (S12)
2-15