TM 11-6625-2638-30
Table 2-3. Test Set Troubleshooting - Continued
STEP
PROCEDURE
NORMAL INDICATION
ABNORMAL INDICATION
CORRECTIVE ACTION
56
Use DVM to measure voltages between each of the following pairs of pins.
J3-Z and J3-q.
8.94 to 9.04 vat.
Out of tolerance.
J3-j and J3-m.
3.03 to 3.13 vat.
Out of tolerance.
J3-p and J3-b.
3.03 to 3.13 vat.
Out of tolerance.
Same voltage as J3-m, check continuity and correct wiring as required.
57
Place POWER switch to OFF.
AC and DC lamps off.
2-28