TM 5-6675-348-13&P
NOTE
Leave approximately 16 in. (40.6 cm)
of Mainfall Slope Sensor Cable on
female end, for storage, as shown.
(95) Install Mainfall Slope Sensor Cable (72),
Loop Clamp (73), washer (74), bolt (67) to
Mainfall Slope Sensor Bracket (66).
NOTE
Connector holder mounting screw is larger
than hole in dust cap.
(96) Ream connector holder (75) mounting hole
with rat-tail file.
(97) Install screw (76) and connector
holder (75) to outer rear hole of Mainfall
Slope Sensor Bracket (66).
(98) Install two cable ties around Rotating Eye
Bracket (77).
(99) Route Mainfall Slope Sensor Cable (72)
under Gooseneck (27).
(100) Attach Mainfall Slope Sensor Cable (72)
with two ties secured by cable ties
installed in Step (98).
(101) Route Mainfall Slope Sensor Cable (72)
under left-side Gooseneck (27) toward
rear of 130G Grader.
3-101