TM 9-4931-355-14
1. Connector P1-MS3126F-20-41-PN
3. Cover 11737513
2. Connector P2-MS3126F-12-10-SN
4. Connector J1-11745550-2
Figure 4-7. Repair of PFN charge ammeter cable
(1) Terminate wires on tester cable, test
(3) After the termination of all wires and the
cables W50 through W54, A75/A76 extension cable,
completion of all soldering, assemble the connector.
branched cable, or PFN charge power supply extender
Assemble connectors, shells, clamps, etc as illustrated
cable per specification MIL-F14256.
on applicable figure.
(2) Solder contacts on cable using solder Sn
60, QQ-S-571.
4-12. Inspection
Refer to chapter 5 for final inspection criteria.
Section VI. REPAIR OF ALINEMENT LENS ASSEMBLY
limited to replacement of the cord assembly at GS level
4-13. General
maintenance.
The repair of the alinement lens assembly is
4-6