TM 11-6625-2638-30
Table 2-3. Test Set Troubleshooting - Continued
STEP
PROCEDURE
NORMAL INDICATION
ABNORMAL INDICATION
CORRECTIVE ACTION
42
Verify that the following pulse occurs when the TRACKING FILTER RESET switch is depressed.
Pulse missing.
Wrong voltage levels.
43
a. Remove jumper wires (do not disconnect signal generator).
b. Connect DVM negative lead to GRD jack.
44
Use DVM to verify logic levels for TRACKING FILTER switch positions as follows:
a. Set TRACKING FILTER switch to ELEV A.
b. Depress and release TRACKING FILTER RESET switch.
TFT
lamp goes off, then comes back on.
J5-d
is 3.5 to 5.5 vdc.
J5-Z
is 3.5 to 5.5 vdc.
J5-c
is 0.0 0.5 vdc.
J5-a
is 0.0 to 0.5 vdc.
Other than above.
2-16