TM 5-6675-348-13&P
Table 3-4. Blade Pro Motor Grader Control System Operator's PMCS (Before/After) (Cont)
Location
Item
Item to
Not Fully Mission
No.
Interval
Check/Service
Procedure
Capable If:
5.
Before/After Remote
Interface Box
To avoid damage to equipment,
fuse must be replaced with
25-amp fuse.
Fuse is blown. Replace
Check 25-amp fuses to ensure they are
before operating.
not burned out.
Dirt, debris, and/or
Check left and right socket connectors
damaged connectors are
for any dirt, debris, or damaged
present.
connections.
Nuts or screws are loose.
Check nuts and screws for tightness.
Check electrical connectors for any
Connectors are damaged.
6.
Before/After Mainfall Slope
dirt, debris, or damage.
Sensor and
Blade Slope
Sensors
Connectors are damaged.
7.
Before/After Circle Rotation
Check electrical connectors for dirt,
Sensor
debris, or damage.
Check screws for tightness.
Connectors are damaged.
Check electrical connectors and
8.
Before/After Tracer Sonic
Transducer is soiled,
transducer for dirt, debris, or damage.
Grade
dented, or foil inside is
Controller
Wipe dirt and dust from housing covers
ripped.
with damp cloth. Inspect exterior for
damage or cracks.
Wipe dirt and dust from transducer,
using soft cloth or low-pressure air.
Connectors are damaged.
9.
Before/After R2S-S Laser
Check electrical connections for dirt,
Receiver
debris, or damage.
Wipe dirt and dust from metal housing
cover with damp cloth.
Windows are cracked or
Inspect windows for cracks and ensure
black dust seal is missing.
black dust seal is still in place.
Clean windows with clean water or
general purpose cleaner and soft cloth.
Check and clean breather hole.
Breather hole is plugged.
3-20