TM 5-6675-348-13&P
Level 1 Errors
Abbreviation
Error #
Blade slope signal detected with sensor OFF.
Blade On
User turned OFF Blade Slope Sensor but did not disconnect it.
1
Remote Interface Box CPU board.
Mainfall On
Mainfall signal detected with sensor OFF.
2
User turned OFF Mainfall Slope Sensor but did not disconnect it.
Remote Interface Box CPU board.
Rotation On
Rotation angle signal detected with sensor OFF.
3
User turned OFF rotation Angle Sensor but did not disconnect it.
Remote Interface Box CPU board.
Articulation
Articulation angle signal detected with sensor OFF.
On
4
User turned OFF articulation Angle Sensor but did not disconnect it.
Remote Interface Box CPU board.
Error #
Abbreviation
Level 2 Errors
No Valve
Valve type not selected.
Selected
5
User did not yet select a valve type.
Remote Interface Box CPU board.
Blade Slow
Blade slope signal frequency too low or stopped with sensor ON.
Blade Slope Sensor or cable.
6
Remote Interface Box CPU board.
Remote Interface Box motherboard.
Blade Fast
Blade slope signal frequency too high with sensor ON.
Blade Slope Sensor or cable.
7
Remote Interface Box CPU board.
Remote Interface Box motherboard.
Blade Low
Blade slope signal value too low with sensor ON.
Blade Slope Sensor or cable.
8
Remote Interface Box CPU board.
Remote Interface Box motherboard.
Blade High
Blade slope signal value too high with sensor ON.
Blade Slope Sensor or cable.
9
Remote Interface Box CPU board.
Remote Interface Box motherboard.
Mainfall Slow
Mainfall signal frequency too low or stopped with sensor ON.
Mainfall Slope Sensor or cable.
10
Remote Interface Box CPU board.
Remote Interface Box motherboard.