TM 11-6625-2638-30
Table 2-2. Fault Symptom Chart - Continued
GROUP
CONTROL/lNDICATOR/JACK
CORRECTIVE ACTION
9
RCVR Test Jacks
Check continuity of suspected jack per wirelist (table 2-4).
10
QDRT and GIMBAL COMD Group
QDRT lamps
GIMBAL COMD switch
Notify higher category maintenance.
11
SERVO Group
+ and Jacks
Check continuity of suspected jack per wirelist (table 2-4).
SERVO Switch
Notify higher category maintenance.
12
RCVR CURRENT Group
Check continuity of suspected jack per wirelist (table 2-4).
13
MOTOR PWR, AZIMUTH GAIN, LED PRF and MLO Switches
MOTOR PWR
Perform steps 1 thru 10 and 16 thru 19 of table 2-3.
AZIMUTH GAIN
LED PRF
MLO
14
DVM/SCOPE switch and ELECT SCOPE/DVM Jacks
15
POWER
16
RCVR CURRENT Group
Check continuity of suspected jack per wirelist (table 2-4)
2-5