TM 5-6675-348-13&P
Table 5-3. 1145-2 Laser Transmitter Troubleshooting (Cont)
Malfunction
Test or Inpsection
Corrective Action
FAULT 5-2. LASER BEAM WILL NOT SHUT OFF WHEN 1145-2 LASER
Step 1.
Ensure Control Switch (1) is in AUTO position.
FAULT 5-3. 1145-2 LASER TRANSMITTER LOW
VOLTAGE INDICATOR LAMP IS ON
.
Connecting to 24 Vdc will damage laser. Ensure external power is 12 Vdc. Failure to
comply will result in damage to equipment
Step 1.
Charge internal Battery using Power/Charge Connector (1).
Step 2.
Verify sufficient charge in your external 12-Vdc battery (2).
Step 3.
Check Power/Charge Connector (1) for dirt.
If Power/Charge Connector (1) is dirty, clean with clean cloth.
Step 4.
Ensure twist-lock ring on Power Cord (3) is snapped in place.
Step 5.
Check for a broken or frayed wire in Power Cord (3), particularly at receptacle end.