TM 11-5860-200-12
NOTE
If RU FAULT or EU FAULT lamp lights in TEST mode, rotate MODE switch to STBY
and back to TEST. If either fault lamp lights again, refer to table 3-3.
TRACK lamp (2) may light a few times during TEST mode.
b. Set MODE switch (1) to TEST.
c. Wait about 25 seconds until GO lamp (5) and TRACK lamp (2) lights.
d. Set MODE switch (1) to STBY. Check that TRACK lamp (2) goes out, and GO lamp (5) will turn off after about
30 seconds.
Figure 3-5. ALT Control Panel.
3-8