TM 11-5860-200-12
Table 3-3. ALT Troubleshooting Procedures.
SYMPTOM
POSSIBLE CAUSE
CORRECTIVE ACTION
Press-to-test lamps do
No lamp circuit power.
Ensure aircraft switches
not light when pressed
are in proper position
on control panel.
Defective lamps.
RU FAULT lamp on
Connectors on receiver
Check security and
control panel lights
and boresight mount
proper mating of con-
during TEST mode.
may not be properly
nectors.
mated.
Failure in receiver.
Replace receiver (para
Failure in electronics
Replace electronics
assembly.
EU FAULT lamp on
Connectors on electron-
Check security and
control panel lights
ics assembly not prop-
proper mating of con-
during TEST mode.
erly mated.
nectors.
Failure in electronics
Replace electronics
assembly.
Failure in receiver.
Replace receiver
RU FAULT, EU FAULT
Failure in electronics
Replace electronics
and GO lamps on con-
assembly.
trol panel do not light
Failure in receiver
Replace receiver
assembly (check gimbal
freedom).
3-15