TM 11-6625-2685-23
Section Ill. TROUBLESHOOTING PROCEDURE
3-6. Alignment Set Troubleshooting
Troubleshooting of the alignment set consists of fault isolation of the laser simulator. Perform troubleshooting of the
alignment set as indicated in table 3-1, fault symptoms.
Table 3-1. Laser Simulator Fault Symptom Chart
Corrective Action
Fault Symptom
a. Ensure dimmer is open (CCW).
BATTERY TEST does not light
when indicator is pressed.
a. Inspect the laser simulator lens. If dirty, clean accord-
ALT will not lock onto the simu-
Iated laser beam.
category maintenance.
Laser simulator works only in HI
or LO mode but not in both
modes.
3-2